**Precautions for Using a Microplate Reader**
A microplate reader is a precision optical instrument, and maintaining an appropriate working environment is essential to ensure its accuracy, stability, and longevity. Here are key guidelines to follow:
1. **Working Environment**
- Place the instrument in an area free from strong magnetic fields and electrical interference.
- Ensure the ambient noise level is below 40 decibels for optimal performance.
- Avoid direct sunlight to prevent damage to sensitive optical components.
- Maintain a temperature between 15°C and 40°C, with humidity levels ranging from 15% to 85%.
- Ensure a stable power supply during operation to avoid fluctuations that may affect results.
- Keep the operating area clean, dry, and free from dust, water vapor, and smoke.
- Provide a flat, stable work surface with enough space for safe and efficient use.
2. **Operation Precautions**
- Always follow standardized procedures when using the microplate reader to reduce variability.
- Do not mix pipette tips with different pipettes to avoid cross-contamination.
- Thoroughly wash the microplate to prevent contamination between samples.
- Follow the manufacturer’s instructions precisely, including accurate reaction times.
- Avoid spilling samples or reagents on the instrument’s surface or internal parts.
- Never turn off the power during a measurement process, as this may lead to data loss.
- If test results deviate due to kit-related issues, adjust parameters accordingly for better accuracy.
- Always cover the instrument with its dust cover after use to protect it from dust and damage.
- In case of technical problems, contact the manufacturer immediately and do not attempt to disassemble the device yourself.
3. **Common Issues with ELISA/EIA Kits**
- Different manufacturers may have slight variations in their kits, so always follow the specific instructions provided with the kit you are using.
- Mixing reagents from different batches (such as A solution or enzyme working solution) can lead to inconsistent results, such as weak color development or high background.
- Sample volume errors can significantly impact results, especially for samples near the threshold. It's recommended to calibrate the pipette regularly.
- Inconsistent reaction times, particularly when processing multiple samples, can cause discrepancies between the first and last wells.
- Manual pipetting may introduce variability due to differences in drop size, bubble formation, or uneven speed. For high-precision applications, a calibrated pipette is strongly advised.
- The threshold for positive/negative results is often a gray zone. Some foreign manufacturers require retesting of ambiguous samples to confirm the result. This does not necessarily mean the result is incorrect, but rather that further clinical evaluation is needed.
- Visual inspection of results is unreliable. Even if a sample appears negative to the naked eye, the microplate reader should be used for accurate readings.
- Sudden changes from negative to strongly positive results are often due to reagent leakage or improper handling during the procedure.
By following these precautions and being mindful of potential issues, users can ensure more reliable and consistent results when using a microplate reader.