Spot person asymmetric dimethylarginine ELISA detection kit

Specimen: serum or plasma

Test principle: The ADMA kit is a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA). Standards with known ADMA concentrations and samples with unknown concentrations are added to microwell enzyme plates for detection. First, ADMA and biotin-labeled antibodies are incubated simultaneously. After washing, HRP labeled with avidin was added. After incubation and washing, the unbound enzyme conjugate is removed, and then substrates A and B are added to act simultaneously with the enzyme conjugate. Produce colors. The color depth is proportional to the concentration of ADMA in the sample.

Bring your own material distilled water. Sampler: 5ul, 10ul, 50ul, 100ul, 200ul, 500ul, 1000ul. Oscillator and magnetic stirrer etc. Safety Avoid direct contact with the stop solution and substrates A and B. Once exposed to these liquids, rinse with water as soon as possible. Do not eat, drink, smoke or use cosmetics during the experiment. Do not use your mouth to absorb any ingredients in the kit. Handling precautions Reagents should be stored according to label instructions, and returned to room temperature before use. The sparse standards should be discarded and cannot be stored. The slats not used in the experiment should be immediately returned to the packaging bag, sealed and stored to avoid deterioration. Unused other reagents should be packed or covered. Do not mix reagents of different batches. Use before warranty. Use a disposable pipette tip to avoid cross-contamination, and avoid using a sampler with a metal part when drawing the stop solution and substrates A and B. Use a clean plastic container to prepare the washing solution. Mix all components and samples in the kit thoroughly before use. When washing the enzyme-labeled plate, it should be fully patted dry. Substrate A should evaporate to avoid opening the lid for a long time. Substrate B is sensitive to light and avoid prolonged exposure to light. Avoid contact with hands, it is toxic. The OD value should be read immediately after the experiment is completed. The order of adding reagents should be the same to ensure that all wells are incubated for the same time. Perform the incubation operation according to the time, the amount and order of the liquid indicated in the instructions. Human asymmetric dimethylarginine ELISA detection kit sample collection, processing and storage methods Serum ----- Avoid any cell stimulation during the operation. Use test tubes free of pyrogens and endotoxins. After collecting blood, centrifuge at 1000 × g for 10 minutes to separate the serum and red blood cells quickly and carefully. Plasma ----- EDTA, citrate, heparin plasma can be used for detection. Centrifuge at 1000 × g for 30 minutes to remove particles. The cell supernatant was centrifuged at 1000 × g for 10 minutes to remove particles and polymers. Storage ------ If the sample is not used immediately, it should be divided into small parts and stored at -70 ℃ to avoid repeated freezing. If possible, do not use hemolysis or hyperlipidemia. If there are a large number of particles in the serum, centrifuge or filter before testing. Do not thaw at 37 ° C or higher. Thaw at room temperature and ensure that the sample is thawed evenly and adequately.

Reagent preparation standards: Serial dilutions of standards should be prepared during the experiment and cannot be stored. Before dilution, the standard was mixed by shaking. Dilution of washing buffer (50 ×): 50-fold dilution with distilled water. Before use, mix all reagents thoroughly. Don't make the liquid generate a lot of foam, so as to avoid adding a large number of bubbles during sample addition, which will cause errors in sample addition. The number of slats required is determined by the number of samples to be tested plus the number of standard products. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used as much as possible. Add 50ul of the diluted standard to the reaction well and 50ul of the sample to be tested in the reaction well. Immediately add 50ul of biotin-labeled antibody. Cover the membrane plate, gently shake and mix, and incubate at 37 ° C for 1 hour. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 80 ul of streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 50ul of substrate A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid light. Remove the enzyme labeling plate and quickly add 50ul of stop solution. After adding the stop solution, the results should be measured immediately. The OD value of each well was measured at a wavelength of 450 nm. The results of the human asymmetric dimethylarginine ELISA detection kit limited to standard No. 6 and above are non-linear, and accurate results cannot be obtained according to this standard curve.

Kit performance 1. Sensitivity: The minimum detection concentration is less than No. 1 standard. Linearity of dilution. The correlation coefficient between the linear regression of the sample and the expected concentration is 0.990. 2. Specificity: Does not react with other cytokines. 3. Repeatability: The coefficients of variation within and between plates are less than 10%.

Judgment and analysis of results 1. Instrument value: read the OD value of each well on a microplate reader with a wavelength of 450 nm. 2. Take the absorbance OD value as the ordinate (Y), and the corresponding ADMA standard concentration as the abscissa (X). To make the corresponding curve, the ADMA content of the sample can be converted from the standard curve to the corresponding concentration according to its OD value. 3. Detection value range: 0-40umol / L4, sensitivity: 0.1 umol / L human asymmetric dimethylarginine ELISA detection kit DA2093-0.2ml IFITM1 (interferon induced transmembrane protein 1) interferon induced transmembrane protein 1 Antibody 0.2ml DA2094-0.1ml human IFN-β (Interferon β) interferon-β antibody (anti-human) 0.1ml DA2094-0.2ml human IFN-β (Interferon β) interferon-β antibody (anti-human) 0.2ml DAR1011-0.3 ml Goat IgG / RBITC Rhodamine-labeled goat IgG (cell flow isotype control) 0.3mlDAR1012-0.3ml Rat IgG / RBITC Rhodamine-labeled rat IgG (cell flow isotype control) 0.3mlDAR1013-0.3ml Rabbit anti-chicken IgG / RBITC Rhodamine labeled rabbit anti-chicken IgG 0.3ml DAR1014-0.3ml Rabbit anti-Guinea IgG / RBITC Rhodamine labeled rabbit anti-guinea pig IgG 0.3ml DAR1015-0.3ml Goat anti-bovine IgG / RBITC Rhodamine labeled goat anti-bovine IgG 0.3ml DA2095-0.1 ml human IFN-α (Interferon α) interferon-α antibody (anti-human) 0.1ml DA2095-0.2ml human IFN-α (Interferon α) interferon-α antibody (anti-human) 0.2ml

Kitchenware

Different kinds of kitchenware can help your kitchen organized prefect. We have many different kinds excellent quality kitchenware ,such as canister set, Oil Kettle ,tissues holder, condiment ,water kettle Measuring Spoon Set and so on.

Any items need to know more ,welcome to contact us directly, we would be willing to answer you and provide the good service to you.

potato ricer tissues holderoil kettle

 

FAQ:


1:How can I get the sample?

We can provide the sample for customers to check the quality.

Please kindly provide the delivery info for calculate the sample cost. If you have DHL /TNT/UPS/FEDEX account, please also kindly provide it to us.

You can do the payment of sample via T/T and PayPal.


2:How about the sample time?

Usually the sample time is 7~10 days after have the sample cost.


3:How long will it take for mass production?

Usually 45~60 days after have the deposit.


4:Can we have our logo or company name to be printed on your products or the package?

Welcome OEM.


5:what certificate can you provide?

CE,CB,GS,FDA,LFGB,ROHS are available here.


6:How can we get your monthly new products announcement?

Please join our mailing lists.


Kitchenware

Stainless Steel Colander ,Paper Towel Holder,Measuring Spoon,Measuring Cup

Jiangmen Wellway Houseware Co.,Ltd , https://www.wellwayhouseware.com